Mechanical Timer Switch Manual

Item #1000-015-595
  1. Leviton Mechanical Timer
  2. Outdoor Mechanical Timer Switch
  3. Mechanical Timer Switch Manual
  4. Mechanical Timer Switch Manual Diagram
  5. 470906 Wall Switch Timer Instructions
INDOOR BASIC TIMER
Please contact 1-866-308-3976 for further assistance.
6

Switches & Timers USB Wall Outlets / Chargers Wallplates Residential Accessories Color Change Kits. Manual Motor Controllers Safety Disconnect Switches. Alibaba.com offers 1,048 manual timer switch products. About 22% of these are time switches, 18% are timers, and 2% are wall switches. A wide variety of manual timer switch options are available to you, such as timer switch, multifunctional, and kitchen.

  1. 15336 - Acti 9 - IH - mechanical time switch - 24 h - 100 h memory. View the new All Products menu. Browse Products by Master Ranges. Manual time changeover. Measurement accuracy +/- 1 s/day 20 °C. Power consumption in VA: 2.5 VA. Maximum switching current: 16 A - 250 V AC pf = 1.
  2. Read and download GE Timers PlugIn 15119 24 hour Mechanical Timer Owner's Manual online. Download free GE user manuals, owners manuals, instructions, warranties and installation guides, etc.
  3. Use and Care GuideItem #1000-015-595INDOOR BASIC TIMERPre-OperationInstallationPACKAGE CONTENTSWARNING: Turn the power off at the circuit breaker or fuse box before installation.NOTE: For use with single-pole, one switch permanently installed applications.75431 PREPARING THE TIMER FOR INSTALLATION 10126 5 4 311 4TIMERB6 5 4 3OFFa.
  4. Timer Controls In-Wall Controls Photocontrols. Analog/Mechanical Time Switches. View Products Specialty Time Switches. View Products Enclosures. View Products Accessories. View Products Subscribe to Our Newsletter Sign-up for email alerts for products and software updates, new product releases and information about upcoming events.
  5. In order to operate the wall switch/mechanical timer. OPERATING YOUR PETERSON GAS LOG SET WITH THE WALL SWITCH OR MECHANICAL TIMER Wall Switch: To turn on your log set with the wall switch, turn the wall switch to the ON position and the log set will light. To turn off your log set, turn the wall switch to the OFF position.
4
2
11
9
7
10
8
6
Mechanical Timer Switch Manual
4
2
OFFTIMER
WARNING
Shut off the power at the fuse box or circuit breaker
Do not use in wet locations
RISK OF ELECTRIC FIRE:
Use only copper wire
Do not use to control appliances that contain heating
elements such as cooking appliances, heaters, and irons
OFF
D
5
3
1
10
8
11
9
7
5
3
1
BA
PREPARING THE TIMER FOR INSTALLATION
a. Remove the existing wall plate and existing single-pole
b.Using a dime, gently turn the center screw (A)
counterclockwise. Remove the center pin (B) and the
c.Strip wires to 3/8 in. long.
CONNECTING THE WIRES
a. Connect the green wire from the timer to the green
b.Connect the white wire from the timer to the neutral wire
from the outlet. Often the neutral (white) wire can be
found in the back of the wire box connected with a wire
nut. There may be several neutral wires bound together.
Add the neutral to all neutral wires bound together
c.Connect the black wire from the timer to the line wire
d. Connect the red wire from the timer to the load wire
e.If you are uncertain as to which wire is which or cannot
locate your neutral wire, please consult a certied
f.Secure all four wiring connections using the wire nuts
(AA) and gently tuck the connections into the outlet box
WHITE
RED
GREEN
LOAD
AA
Black

Leviton Mechanical Timer

Load
WhiteWhite
Green
Typical Wiring Schematic
Mechanical
3
a. Mount the timer (D) securely with the mounting screws
b.Install your rocker decora style wall plate over the
screws to secure.
c.Replace the timer dial (C), center pin (B), and center
d. Restore power at the fuse box or circuit breaker.
5
3
1
10
8
11
9
7
5

Outdoor Mechanical Timer Switch

3
1
TIMER
D
BBC
ACenter Screw
CDial
6
4
2
11
9
7

Mechanical Timer Switch Manual

10
8
6
4
2
OFFTIMER
D
B
PRODUCT DESCRIPTION
6
4
2
11
9
7
10
8
6
4
2
Mechanical Timer Switch Manual
OFF
1
2
D
PROGRAMMING THE TIMER
a. Ensure all segments (1) are pulled inward before programming.
b.Place the slide switch (2) on the timer (D) to the TIMER position.
c.Rotate the dial (C) clockwise until the current time lines up with
d. Select a time period (or periods) you want the device turned
on, then push outward all the segments (1) that fall on or
within that time period. For example, to have the timer turn a
lamp on at 10 PM and off at 2 AM, push outward the segments
(1) representing 10 PM and 2 AM, and all the segments (1) in
between. You may need to turn the dial (C) clockwise to access
the desired segments. Nighttime hours (from 6:30 PM to 6:30
WARNING:Turn the power off at the circuit breaker or fuse box before installation.
NOTE: For use with single-pole, one switch permanently installed applications.

Mechanical Timer Switch Manual Diagram

125 VAC, 15A Resistive
125VAC,1250W Tungsten
125VAC, 500VA Electronic Ballast
The manufacturer guarantees this product to be free of
defects in materials and workmanship for 1 year from the
date of purchase. If this product is defective, call 866-308-

470906 Wall Switch Timer Instructions

3976 for repair or replacement parts or return the product to
the store from which it was purchased. This guarantee does
not include normal wear and tear, LEDs, or batteries.
NOTE: Remember to install your wall plate over the timer (D) before you replace the dial (C), center pin (B), and center screw (A).